Turbo PMAC2 PCI Hardware Reference Manual
40 Baseboard Connector Pinouts
J12 (JMACH4) Connector Description (Continued)
Pin # Symbol Function Description Notes
96 PWMCBOT8-
PULSE8-
Output Phase B bottom CMD or PFM
pulse
Programmable function control
97 GND Common Reference voltage
98 GND Common Reference voltage
99 +5V Output/Input +5V power For external circuit or from external
supply
100 +5V Output/Input +5V power For external circuit or from external
supply
The JMACH1 connector provides the interface pins for channels 3 and 4. Usually, it is connected to a breakout
board, such as one of the Acc-8x family of boards, or an application-specific interface board.
TB1 (2/4-Pin Terminal Block)
This terminal block can be used to provide the input for the power supply for the circuits on the PMAC2
board when it is not in a bus configuration. When the PMAC2 is in a bus configuration, these supplies
automatically come through the bus connector from the bus power supply; in this case, this terminal block
should not be used.
Pin#
Symbol Function Description Notes
1 GND Common Reference voltage
2 +5V Input Positive supply voltage Supplies all PMAC digital circuits
3 +12V Input Positive supply voltage +12V to +15V; not required
onboard; used on J1 to supply
analog inputs
4 -12V Input Negative supply voltage -12V to -15V; required for Opt-12
ADCs; used on J1 to supply analog
inputs
Note: Unless Option 12 (Analog-to-Digital Converters) is included on the board, only pins 1 and 2 will be
provided on this terminal block.
TB2 (3-Pin Terminal Block)
This terminal block provides the output for PMAC2's watchdog timer relay, both normally open and
normally closed contacts.
Pin#
Symbol Function Description Notes
1 WD_NC Output Watchdog relay out Normally closed
2 COM Input Watchdog return +V or 0V
3 WD_ No Output Watchdog relay out Normally open
Note: The normally closed relay contact is open while PMAC2 is operating properly – it has power and the
watchdog timer is not tripped – and closed when the PMAC2 is not operating properly – either it has lost power or
the watchdog timer has tripped. The normally open relay contact is closed while PMAC2 is operating properly
and open when PMAC2 is not operating properly.