Delta Tau Geo Direct PWM Amplifier Installationshandbuch Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 53
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
Geo Direct PWM Amplifier
Specifications 7
SPECIFICATIONS
Part Number
Main AC Voltage Input:
L = 115 - 230 VAC
H = 300 - 480 VAC
Number of Axes:
1 = Single Axis
2 = Dual Axis
P
Continuous/Peak Current Rating (Sinusoidal Amp rms)
G 0 0 0
0 = No Safety Relay
1 = Safety Relay
01 = 1.5 / 4.5
03 = 3 / 9
05 = 5 / 10
10 = 10 / 20
15 = 15 / 30
20 = 20 / 40
30 = 30 / 60
Environmental Specifications
Description
Specifications
Operating Temperature
0 to 45°C
Above 45°C,de-rate current output by 2.5% per °C
Storage Temperature
-25°C to +70°C
Humidity
10% to 90% non-condensing
Operating Altitude
~3300 Feet (1000 m)
De-rate current output by 1.1% per additional 330 feet (100m)
Air Flow Clearances
~3 inches (76.2mm) above and below unit for air flow
Operating Environment
Pollution Degree 2 or equivalent