Geo Direct PWM Amplifier
Power PMAC3 Drive Setup 39
Caution
At this point of the drive-motor setup, and before tuning the current loop, a couple of sanity checks can be
performed, making sure that:
Enabling the drive with a #nOut0 command does not produce any faults in neither the drive nor the
PMAC.
The current sensors are operating properly by monitoring the current measurements (i.e.
Motor[x].IaMeas, and Motor[x].IbMeas). These should be reporting values fluctuating around 0.
Frozen values, or values greater than 1000 indicate that the current sensors are not functioning
properly, or a software parameter is incorrect (i.e. Gate3[i].AdcAmpStrobe, Motor[x].PhaseOffset,
Motor[x].AdcMask)
Subsequently, the current loop (Motor[x].IiGain, Motor[x].IpfGain, and Motor[x].IpbGain) can be tuned
using the tuning utility in the IDE software. Commutation, encoder feedback, phasing, and position loop
tuning can then be configured for closed loop control.
Note