ADV810.H File
The following table details the M-Variable assignments and memory addresses for the Adv810.h file.
Many of the macros in the Adv810.H file are constant definitions. These constant definitions issue
commands directly between the PMAC and the PMAC NC 32 for Windows program, so they do not have
a variable assignment or address.
Macro Name Default Value/Address Assignment Comment
JOG_X_PLUS CMD"#1j+"
JOG_Y_PLUS CMD"#2j+"
JOG_Z_PLUS CMD"#3j+"
JOG_C_PLUS CMD"#5j+"
JOG_A_PLUS CMD"#6j+"
JOG_X_MINUS CMD"#1j-"
JOG_Y_MINUS CMD"#2j-"
JOG_Z_MINUS CMD"#3j-"
JOG_C_MINUS CMD"#5j-"
JOG_A_MINUS CMD"#6j-"
JOG_STOP_ALL CMD"#1j/ #2j/ 3j/"
RUN_HOME_PROG CMD"&1 B3 R"
JOG_X_HOME CMD"#1HM"
JOG_Y_HOME CMD"#2HM"
JOG_Z_HOME CMD"#3HM"
JOG_C_HOME CMD"#5HM"
JOG_A_HOME CMD"#6HM"
JOG_X_INCR CMD"#1j=*"
JOG_Y_INCR CMD"#2j=*"
JOG_Z_INCR CMD"#3j=*"
JOG_C_INCR CMD"#5j=*"
JOG_A_INCR CMD"#6j=*"
JOG_X_SPEED_I I122
JOG_Y_SPEED_I I222
JOG_Z_SPEED_I I322
JOG_X_LOW 10 X axis low jog speed in
counts per millisecond
JOG_Y_LOW 10 Y axis low jog speed in
counts per millisecond
JOG_Z_LOW 10 Z Axis low jog speed in
counts per millisecond
JOG_X_MED 50 X axis medium jog speed in
counts per millisecond
JOG_Y_MED 50 Y axis medium jog speed in
counts per millisecond
JOG_Z_MED 50 Z axis medium jog speed in
counts per millisecond
JOG_X_HIGH 100 X axis high jog speed in
counts per millisecond
JOG_Y_HIGH 100 Y axis high jog speed in
counts per millisecond